2016年4月5日星期二

Acura Legend ELECTRICAL Five-Step Troubleshooting

Honda Acura Legend ELECTRICAL Five-Step Troubleshooting 
  1. Verify The Complaint
    Turn on all the components in the problem circuit to check the accuracy of the customer complaint. Note the symptoms. Do not begin disassembly or testing until you have narrowed down the problem area.
  2. Analyze The Schematic
    Look up the schematic for the problem circuit. Determine how the circuit is supposed to work by tracing the current paths from the power feed through the circuit components to ground. If several circuits fail at the same time, the fuse or ground is a likely cause.
    Based on the symptoms and your understanding of the circuit operation, identify one or more possi- ble causes of the problem
  3. Isolate The Problem By Testing The Circuit
    Make circuit tests to check the diagnosis you made in step 2. Keep in mind that a logical, simple pro- cedure is the key to efficient troubleshooting. Test for the most likely cause of failure first. Try to make tests at points that are easily accessible.
  4. Fix The Problem
    Once the specific problem is identified, make the repair. Be sure to use proper tools and safe pro- cedures.
  5. Make Sure The Circuit Works
    Turn on all components in the repaired circuit in all modes to make sure you’ve fixed the entire prob- lem. If the problem was a blown fuse, be sure to test all of the circuits on that fuse. Make sure no new problems turn up and the original problem does not recur.
Back to Contents

没有评论:

发表评论